Tablet/Capsule Counter Filler – PQ Protocol

Document ID: PQ-OSD-TCCF-001

Version: 1.0

Effective Date: 2023-10-01

Reviewed By: [Name]

Approval Date: [Date]

Performance Qualification Protocol for Tablet and Capsule Counter Filler

Objective: To validate the performance of the Tablet/Capsule Counter Filler to ensure it meets specified requirements for counting and filling into bottles accurately and efficiently.

Scope: This protocol applies to the validation of the Tablet/Capsule Counter Filler used in the packaging of solid dosage forms within the primary packaging area.

Responsibilities:

  • Validation Team: Ensure the execution of the PQ protocol and documentation of results.
  • Quality Assurance: Review and approve the protocol and results.
  • Operations: Provide access to the equipment and assist in execution of test cases.

Prerequisites:

  • Completion of Installation Qualification (IQ) and Operational Qualification (OQ).
  • Availability of required materials for testing.
  • Training of personnel on the operation of the equipment.

Equipment Description: The Tablet/Capsule Counter Filler is designed for counting and filling solid dosage forms into bottles. It is capable of handling various tablet and capsule sizes with a focus on accuracy and speed.

Test ID Procedure Acceptance Criteria Evidence
PQ-001 Verify counting accuracy with sample tablets/capsules. Counting accuracy within ±1% of target. Count report and audit trail.
PQ-002 Measure fill speed during operation. Fill speed meets specified URS requirements. Speed test report.
PQ-003 Check for rejects during counting and filling. Reject rate ≤ 0.5%. Reject logs and audit trail.
See also  Drum Tippler/Drum Tumbler – Traceability Matrix (URS ↔ Tests)

Detailed Test Cases:

  • Test Case PQ-001: Using a batch of 100 tablets, count and verify accuracy. Document the actual count and compare against the expected count.
  • Test Case PQ-002: Measure the time taken to fill 100 bottles and calculate the fill speed. Ensure it meets the URS specifications.
  • Test Case PQ-003: Monitor the reject count during a 1-hour operation. Document any discrepancies and the corresponding reasons.

Deviations: Any deviations from the acceptance criteria during testing must be documented in a deviation report and reviewed by the Quality Assurance team.

Approvals:

  • Prepared By: [Name/Title]
  • Reviewed By: [Name/Title]
  • Approved By: [Name/Title]

Data Integrity Checks: Ensure that all data collected during the PQ process is logged into a secure electronic system with restricted access. Regular audits of the data should be conducted to verify integrity and compliance with regulatory standards.