Glass Lined Reactor (GLR) – Equipment Validation SOP

Standard Operating Procedure for Equipment Validation of Glass Lined Reactor

Purpose: This SOP outlines the procedures for validating the Glass Lined Reactor (GLR) used in API manufacturing to ensure compliance with regulatory standards and product quality.

Scope: This SOP applies to the validation of the Glass Lined Reactor utilized in the chemical synthesis and purification processes within the production area.

Definitions:

  • GLR: Glass Lined Reactor, an equipment used for chemical synthesis.
  • Validation: The process of establishing documented evidence that a system or process meets its intended use.
  • DQ: Design Qualification.
  • IQ: Installation Qualification.
  • OQ: Operational Qualification.
  • PQ: Performance Qualification.

Roles:

  • Validation Team: Responsible for executing the validation protocol.
  • Quality Assurance: Ensures compliance with regulatory standards and reviews validation documentation.
  • Production Personnel: Operate the GLR and provide input during the validation process.

Lifecycle Procedure:

  1. Conduct Design Qualification (DQ) to ensure the GLR meets user requirements.
  2. Perform Installation Qualification (IQ) to verify the equipment is installed correctly.
  3. Execute Operational Qualification (OQ) to confirm the GLR operates within specified parameters.
  4. Complete Performance Qualification (PQ) to validate the GLR’s performance during actual production conditions.

GDP Controls: Good Documentation Practices must be adhered to throughout the validation process, ensuring all records are clear, accurate, and complete.

Acceptance Criteria Governance: Acceptance criteria will be established based on User Requirements Specifications (URS) and in accordance with Annex 11 and Annex 15 of the applicable regulations.

See also  Drum Lifter – Equipment Validation SOP

Calibration/PM Governance: The GLR must undergo regular calibration and preventive maintenance as per the manufacturer’s recommendations and internal policies to ensure ongoing compliance and performance.

Change Control Triggers: Any modifications to the GLR or its operating procedures must initiate a change control process to assess the impact on validation status.

Revalidation Triggers and Periodic Review: Revalidation is required every 12 months or whenever significant changes occur that may affect the GLR’s performance or compliance.

Records/Attachments List:

  • Validation Protocols (DQ/IQ/OQ/PQ)
  • Calibration and Maintenance Records
  • Change Control Documentation
  • Periodic Review Reports