Purified Water Generation System (PW System) – OQ Protocol

Document Control

Protocol Number: OQ-PW-001

Version: 1.0

Effective Date: [Insert Date]

Prepared by: [Insert Name]

Reviewed by: [Insert Name]

Approved by: [Insert Name]

Operational Qualification Protocol for Purified Water Generation System

Meta Description: This document outlines the Operational Qualification protocol for the Purified Water Generation System, ensuring compliance with regulatory standards.

Tags: Equipment Validation, OQ, Purified Water, Utilities, Pharmaceutical

Objective

The objective of this Operational Qualification (OQ) protocol is to verify that the Purified Water Generation System (PW System) operates within established parameters, ensuring the generation of purified water that meets quality standards.

Scope

This protocol applies to the Purified Water Generation System utilized in the Utilities area for generating purified water, impacting product quality directly.

Responsibilities

  • Validation Team: Responsible for executing the OQ protocol and documenting results.
  • Quality Assurance: Responsible for reviewing and approving the protocol and results.
  • Operations: Responsible for maintaining the equipment in accordance with the protocol.

Prerequisites

  • Completion of Equipment Installation Qualification (IQ).
  • Availability of all necessary documentation and standard operating procedures (SOPs).
  • Training of personnel on the operation of the PW System.

Equipment Description

The Purified Water Generation System is designed to produce purified water for pharmaceutical manufacturing, ensuring compliance with regulatory standards. Key critical parameters include conductivity, TOC, flow, temperature, pressure, and audit trail.

Test Plan

Test ID Procedure Acceptance Criteria Evidence
OQ-001 Measure Conductivity Conductivity ≤ 1.3 µS/cm Conductivity log
OQ-002 Measure TOC TOC ≤ 500 ppb TOC report
OQ-003 Measure Flow Rate Flow rate within specified range (e.g., 1-10 L/min) Flow rate log
OQ-004 Measure Temperature Temperature maintained at 20-25°C Temperature log
OQ-005 Measure Pressure Pressure within specified range (e.g., 10-15 psi) Pressure log
OQ-006 Audit Trail Verification Audit trail logs must be complete and accurate Audit trail report
See also  Bin Blender / IBC Blender – Deviation Impact Assessment

Detailed Test Cases

OQ-001: Measure Conductivity

Procedure: Use a calibrated conductivity meter to measure the conductivity of the output water. Record the value.

OQ-002: Measure TOC

Procedure: Collect a sample of the purified water and analyze for TOC using a validated method. Record the TOC value.

OQ-003: Measure Flow Rate

Procedure: Measure the flow rate of the purified water using a calibrated flow meter. Record the value.

OQ-004: Measure Temperature

Procedure: Use a calibrated thermometer to measure the temperature of the purified water. Record the value.

OQ-005: Measure Pressure

Procedure: Use a calibrated pressure gauge to measure the pressure within the system. Record the value.

OQ-006: Audit Trail Verification

Procedure: Review the audit trail logs for completeness and accuracy. Document any discrepancies.

Deviations

Any deviations from the acceptance criteria must be documented and justified. Corrective actions should be implemented as necessary.

Approvals

This protocol requires approval from the Validation Team, Quality Assurance, and Operations before execution.