Performance Qualification Protocol for Non-Jacketed Mixing Tank
Document Number: PQ-001
Version: 1.0
Effective Date: [Insert Date]
Review Date: [Insert Date]
Objective
The objective of this Performance Qualification (PQ) is to verify that the Non-Jacketed Mixing Tank operates within specified parameters to ensure consistent mixing of non-sterile liquids, thereby meeting product quality standards.
Scope
This protocol applies to the Non-Jacketed Mixing Tank used in the production of oral liquids, syrups, and suspensions in the manufacturing area. It encompasses the validation of the mixing process and the verification of critical parameters.
Responsibilities
- Validation Team: Responsible for executing the PQ protocol and documenting results.
- Quality Assurance: Responsible for reviewing and approving the PQ documentation.
- Production Team: Responsible for operating the mixing tank during the qualification process.
Prerequisites
- Equipment must be installed and operational.
- Operators must be trained on the equipment.
- All necessary documentation must be in place (URS, SOPs, etc.).
Equipment Description
The Non-Jacketed Mixing Tank is designed for the mixing of non-sterile liquids, including oral liquids, syrups, and suspensions. It features adjustable agitation speed and a capacity of [Insert Capacity].
Test Plan
| Test ID | Procedure | Acceptance Criteria | Evidence |
|---|---|---|---|
| PQ-001-A | Measure agitation speed at various settings. | Agitation speed must be within +/- 10% of target. | Calibration records and speed measurement logs. |
| PQ-001-B | Conduct mixing time trials with specified formulations. | Mixing time must not exceed URS specifications. | Trial logs and formulation consistency reports. |
Detailed Test Cases
Test Case 1: Agitation Speed Verification
Procedure: Set the mixing tank to the target agitation speed and verify with a calibrated tachometer. Repeat for all speed settings.
Acceptance Criteria: Agitation speed must be within +/- 10% of target.
Evidence: Document speed readings and calibration certificate.
Test Case 2: Mixing Time Evaluation
Procedure: Prepare specified formulations and initiate mixing. Record the time taken to achieve homogeneity.
Acceptance Criteria: Mixing time must not exceed URS specifications.
Evidence: Document mixing times and visual inspection reports.
Deviations
Any deviations from the acceptance criteria must be documented and investigated. Corrective actions should be taken to address the root cause.
Approvals
Prepared by: ______________________ Date: ___________
Reviewed by: ______________________ Date: ___________
Approved by: ______________________ Date: ___________