Document Number: OQ-001
Version: 1.0
Effective Date: 2023-10-01
Review Date: 2024-10-01
Operational Qualification Protocol for Bin Lifter / IBC Lifter
Objective: To validate the operational performance of the Bin Lifter / IBC Lifter used for IBC handling and docking in the production area.
Scope: This protocol covers the operational qualification of the Bin Lifter / IBC Lifter in the production/material handling area for solid dosage forms.
Responsibilities:
- Validation Team: Execute the qualification protocol.
- Quality Assurance: Review and approve the protocol and results.
- Production Personnel: Assist in the execution of tests as needed.
Prerequisites:
- Installation Qualification (IQ) completed and approved.
- All necessary training for personnel involved in the qualification.
- Access to the Bin Lifter / IBC Lifter and relevant documentation.
Equipment Description:
The Bin Lifter / IBC Lifter is designed for the safe handling and docking of Intermediate Bulk Containers (IBCs) in the production area. It has a load capacity of 1000 kg and features adjustable docking alignment mechanisms.
| Test ID | Procedure | Acceptance | Evidence |
|---|---|---|---|
| OQ-01 | Verify load capacity by loading maximum weight. | Load capacity meets or exceeds 1000 kg. | Load test report. |
| OQ-02 | Check docking alignment with IBC. | Alignment within ±5 mm. | Alignment measurement log. |
Detailed Test Cases:
Test Case OQ-01: Load Capacity Verification
Objective: To ensure the Bin Lifter / IBC Lifter can handle the maximum load capacity.
Procedure: Gradually load the lifter with weights until it reaches 1000 kg. Monitor for any signs of failure.
Acceptance Criteria: The equipment should operate smoothly without any mechanical failure.
Evidence: Documented load test report detailing the weights used and observations.
Test Case OQ-02: Docking Alignment Check
Objective: To verify that the docking mechanism aligns correctly with the IBC.
Procedure: Position the IBC under the lifter and measure the alignment from multiple points.
Acceptance Criteria: The alignment should be within ±5 mm.
Evidence: Alignment measurement log with recorded values.
Deviations:
Any deviations from the acceptance criteria must be documented and investigated. A corrective action plan should be developed and implemented.
Approvals:
___________________________
Validation Team Lead
___________________________
Quality Assurance Representative
___________________________
Production Manager