Oscillating Granulator – PQ Protocol

Performance Qualification Protocol for Oscillating Granulator

Document Control Number: PQ-OSD-OG-001

Version: 1.0

Effective Date: YYYY-MM-DD

Reviewed By: [Name]

Approved By: [Name]

Objective: To validate the performance of the Oscillating Granulator to ensure it meets the specified requirements for size reduction of wet/dry mass in the production of solid dosage forms.

Scope: This protocol applies to the Oscillating Granulator used in the production area for solid dosage forms, focusing on critical parameters impacting product quality.

Responsibilities:

  • Validation Team: Execute the protocol and document results.
  • Quality Assurance: Review and approve the validation documentation.
  • Production Personnel: Operate the equipment as per the protocol requirements.

Prerequisites:

  • Completion of Installation Qualification (IQ) and Operational Qualification (OQ).
  • Training of personnel on the use of the Oscillating Granulator.

Equipment Description: The Oscillating Granulator is a piece of equipment used for the size reduction of wet and dry masses in the production of solid dosage forms. It operates by oscillating a screen to achieve the desired particle size distribution (PSD).

Test ID Procedure Acceptance Criteria Evidence
PQ-01 Verify speed settings during operation. Speed must be within specified range as per URS. Calibration logs and operational records.
PQ-02 Check screen size used for granulation. Screen size must match specifications outlined in URS. Screen specifications and visual inspection.
PQ-03 Assess output particle size distribution (PSD). Output PSD must conform to specifications detailed in URS. PSD analysis report.
See also  Pneumatic Conveying (Dense Phase) – Equipment Validation SOP

Detailed Test Cases:

  • Test Case PQ-01: Operate the granulator at specified speeds and document the readings. Ensure that the speed remains within the acceptable range.
  • Test Case PQ-02: Inspect the installed screen size and verify against the specifications. Document any discrepancies.
  • Test Case PQ-03: Collect samples of granulated material and perform PSD analysis. Compare results to the acceptance criteria.

Deviations: Any deviations from the acceptance criteria must be documented and justified. A deviation report should be submitted to Quality Assurance for review.

Approvals:

  • _____________________
    [Name]
    Validation Team Lead
  • _____________________
    [Name]
    Quality Assurance