Mass Flow Controller (Gas) (CAL-0083) – Calibration Documents

Calibration Documents: Mass Flow Controller (Gas) (CAL-0083) Asset ID CAL-0083 Equipment Mass Flow Controller (Gas) Equipment Type Mass Flow Controller Department Biologics Area/Location Process Gases Process Use Gas control Parameter Flow Units sccm Range Min 0 Range Max 5000 Acceptance…

Rotameter (Gas) (CAL-0084) – Calibration Documents

Calibration Documents: Rotameter (Gas) (CAL-0084) Asset ID CAL-0084 Equipment Rotameter (Gas) Equipment Type Rotameter Department Utilities Area/Location Gas Room Process Use Gas flow Parameter Flow Units L/min Range Min 0 Range Max 50 Acceptance Criteria ±5% Calibration Frequency (days) 365…

pH Meter Bench (CAL-0090) – Calibration Documents

Calibration Documents: pH Meter Bench (CAL-0090) Asset ID CAL-0090 Equipment pH Meter Bench Equipment Type pH Meter Department QC Area/Location Chemistry Lab Process Use pH measurement Parameter pH Units pH Range Min 1 Range Max 14 Acceptance Criteria ±0.02 Calibration…

pH Meter Portable (CAL-0091) – Calibration Documents

Calibration Documents: pH Meter Portable (CAL-0091) Asset ID CAL-0091 Equipment pH Meter Portable Equipment Type pH Meter Department Production Area/Location Process Area Process Use pH checks Parameter pH Units pH Range Min 1 Range Max 14 Acceptance Criteria ±0.05 Calibration…

Inline pH Sensor (Bioreactor) (CAL-0092) – Calibration Documents

Calibration Documents: Inline pH Sensor (Bioreactor) (CAL-0092) Asset ID CAL-0092 Equipment Inline pH Sensor (Bioreactor) Equipment Type Inline pH Sensor Department Biologics Area/Location Bioreactor Process Use pH control Parameter pH Units pH Range Min 1 Range Max 14 Acceptance Criteria…

Conductivity Meter Bench (CAL-0093) – Calibration Documents

Calibration Documents: Conductivity Meter Bench (CAL-0093) Asset ID CAL-0093 Equipment Conductivity Meter Bench Equipment Type Conductivity Meter Department QC Area/Location Chemistry Lab Process Use Conductivity Parameter Conductivity Units µS/cm Range Min 0 Range Max 2000 Acceptance Criteria ±1% Calibration Frequency…

Inline Conductivity Sensor (PW) (CAL-0094) – Calibration Documents

Calibration Documents: Inline Conductivity Sensor (PW) (CAL-0094) Asset ID CAL-0094 Equipment Inline Conductivity Sensor (PW) Equipment Type Inline Conductivity Sensor Department Utilities Area/Location PW Loop Process Use Conductivity Parameter Conductivity Units µS/cm Range Min 0 Range Max 2000 Acceptance Criteria…

Inline Conductivity Sensor (WFI) (CAL-0095) – Calibration Documents

Calibration Documents: Inline Conductivity Sensor (WFI) (CAL-0095) Asset ID CAL-0095 Equipment Inline Conductivity Sensor (WFI) Equipment Type Inline Conductivity Sensor Department Utilities Area/Location WFI Loop Process Use Conductivity Parameter Conductivity Units µS/cm Range Min 0 Range Max 2000 Acceptance Criteria…

TOC Analyzer Offline (CAL-0096) – Calibration Documents

Calibration Documents: TOC Analyzer Offline (CAL-0096) Asset ID CAL-0096 Equipment TOC Analyzer Offline Equipment Type TOC Analyzer Department QC Area/Location Water Lab Process Use TOC Parameter TOC Units ppb Range Min 0 Range Max 1000 Acceptance Criteria ±5% Calibration Frequency…

TOC Analyzer Online (CAL-0097) – Calibration Documents

Calibration Documents: TOC Analyzer Online (CAL-0097) Asset ID CAL-0097 Equipment TOC Analyzer Online Equipment Type Online TOC Analyzer Department Utilities Area/Location WFI Loop Process Use TOC Parameter TOC Units ppb Range Min 0 Range Max 1000 Acceptance Criteria ±5% Calibration…