Cap Tightening / Capping Machine – PQ Protocol

Performance Qualification Protocol for Cap Tightening / Capping Machine in Ophthalmics Production

Document Number: PQ-CTCM-001

Version: 1.0

Effective Date: [Insert Date]

Review Date: [Insert Date]

Prepared By: [Your Name]

Approved By: [Approver’s Name]

Objective

The objective of this Performance Qualification (PQ) protocol is to ensure that the Cap Tightening / Capping Machine operates consistently and reliably within predefined specifications to meet the requirements for the production of sterile eye drops and ointments.

Scope

This protocol applies to the Cap Tightening / Capping Machine used in the production area for the capping of sterile eye drops and ointments. It covers the validation of critical parameters affecting product quality.

Responsibilities

  • Validation Team: Responsible for executing the PQ protocol and documenting results.
  • Quality Assurance: Responsible for reviewing and approving the PQ protocol and results.
  • Production Team: Responsible for operating the equipment as per the validated procedures.

Prerequisites

  • Completion of Installation Qualification (IQ) and Operational Qualification (OQ).
  • Availability of all necessary materials and equipment for testing.
  • Training of personnel on the operation of the Cap Tightening / Capping Machine.

Equipment Description

The Cap Tightening / Capping Machine is designed to securely cap bottles containing sterile eye drops and ointments. The machine features adjustable torque settings to ensure proper sealing and prevent contamination.

Test Plan

Test ID Procedure Acceptance Criteria Evidence
PQ-01 Verify torque range settings Torque range within specified limits Calibration report
PQ-02 Audit trail review No discrepancies in audit trail Audit trail logs
PQ-03 Reject logic functionality test Machine rejects improperly capped bottles Test run records
See also  Bottle Washing / Rinsing Machine – IQ Protocol

Detailed Test Cases

Test Case 1: Verify Torque Range Settings

Objective: To ensure the torque settings are within the specified limits.

Procedure: Set the machine to the specified torque range and measure using a torque gauge.

Acceptance Criteria: Torque range must be within limits defined in the URS Annex11.

Evidence: Record the torque measurements and compare with acceptance criteria.

Test Case 2: Audit Trail Review

Objective: To confirm that the machine maintains a complete and accurate audit trail.

Procedure: Access the machine’s audit trail and review for discrepancies.

Acceptance Criteria: No discrepancies should be present in the audit trail.

Evidence: Document any findings and ensure they are addressed.

Test Case 3: Reject Logic Functionality Test

Objective: To verify that the reject logic functions correctly.

Procedure: Run a series of capping tests with intentional errors and confirm rejection.

Acceptance Criteria: The machine must reject all improperly capped bottles.

Evidence: Collect data from test runs and document outcomes.

Deviations

Any deviations from the protocol must be documented and justified. A deviation report should be completed and submitted for review by Quality Assurance.

Approvals

Prepared by: ____________________ Date: ____________

Approved by: ____________________ Date: ____________