Checkweigher (Inline) – OQ Protocol

Document ID: OQ-CHK-001

Version: 1.0

Effective Date: 2023-10-01

Review Date: 2024-10-01

Operational Qualification Protocol for Inline Checkweigher in Ophthalmics Packaging

Meta Description: This document outlines the Operational Qualification protocol for an inline checkweigher used in the packaging of sterile eye drops and ointments, ensuring compliance with critical parameters.

Tags: Equipment Validation, Ophthalmics, Inline Checkweigher, Operational Qualification

Objective

The objective of this Operational Qualification (OQ) protocol is to verify the performance of the inline checkweigher used in the packaging of sterile eye drops and ointments, ensuring compliance with specified acceptance criteria and regulatory requirements.

Scope

This protocol applies to the inline checkweigher utilized in the packaging area for ophthalmic products, specifically sterile eye drops and eye ointments. The OQ will confirm that the equipment operates within defined parameters and meets the product impact requirements.

Responsibilities

  • Validation Team: Conduct the OQ and document results.
  • Quality Assurance: Review and approve the OQ protocol and results.
  • Operations: Ensure equipment is maintained and calibrated prior to OQ execution.

Prerequisites

  • Equipment must be installed and operational.
  • Calibration records must be available and up-to-date.
  • Staff must be trained on equipment operation.

Equipment Description

The inline checkweigher is a critical piece of equipment used to verify the fill weight of sterile eye drops and ointments during the packaging process. It ensures that products meet specified weight criteria to maintain product integrity and compliance.

See also  Sigma Mixer / Kneader – IQ Protocol

Test Plan

Test ID Procedure Acceptance Criteria Evidence
OQ-CHK-01 Verify accuracy of weight measurement using calibrated weights. Weight measurements must be within ±0.5g of the target weight. Calibration report, weight measurement logs.
OQ-CHK-02 Test reject logic functionality with out-of-spec weights. System must reject any weight outside of acceptance criteria. Test logs, system alerts.
OQ-CHK-03 Audit trail verification for weight measurements. Audit trail must accurately reflect all measurements and rejections. Audit trail report.

Detailed Test Cases

Test Case OQ-CHK-01: Accuracy Verification

Procedure: Use calibrated weights to verify the accuracy of the inline checkweigher. Record the measured weights and compare them against the known values.

Expected Result: All measurements fall within ±0.5g of the target weight.

Test Case OQ-CHK-02: Reject Logic Functionality

Procedure: Introduce weights that are outside the acceptance criteria and verify that the system rejects these weights appropriately.

Expected Result: The system must reject any weight outside the specified range and log the rejection.

Test Case OQ-CHK-03: Audit Trail Verification

Procedure: Review the audit trail generated by the inline checkweigher for completeness and accuracy. Ensure all weight measurements and rejections are logged.

Expected Result: The audit trail must show a complete record of all transactions, including timestamps and user IDs.

Deviations

Any deviations from the acceptance criteria must be documented and assessed for impact on product quality. A corrective action plan should be developed if necessary.

Approvals

Prepared by: ______________________

Date: ______________________

Reviewed by: ______________________

Date: ______________________

Approved by: ______________________

Date: ______________________