Grade A/B/C/D Cleanrooms (Facility Qualification) – IQ Protocol

Installation Qualification Protocol for Grade A/B/C/D Cleanrooms

Document Control:

Document Number: IQ-001

Version: 1.0

Effective Date: [Insert Date]

Review Date: [Insert Date]

Objective

The objective of this Installation Qualification (IQ) protocol is to ensure that the Grade A/B/C/D cleanrooms are installed correctly and meet the specified requirements for aseptic processing environments.

Scope

This protocol applies to the facility qualification of Grade A/B/C/D cleanrooms used in the manufacturing of sterile injectables. It encompasses all engineering aspects necessary for compliance with regulatory standards.

Responsibilities

The following personnel are responsible for the execution and oversight of this protocol:

  • Validation Manager: Overall responsibility for validation activities.
  • Quality Assurance: Ensure compliance with regulatory standards and documentation.
  • Engineering Team: Conduct the installation and testing of cleanroom environments.

Prerequisites

  • Completion of design and construction of cleanroom facilities.
  • Approval of User Requirement Specification (URS).
  • Availability of necessary testing equipment and materials.

Equipment Description

The Grade A/B/C/D cleanrooms are designed to provide a classified environment for aseptic processing. The facility is equipped with controlled HVAC systems, HEPA filtration, and monitoring systems to ensure compliance with ISO standards.

Test Plan

Test ID Procedure Acceptance Criteria Evidence
IQ-01 ISO Class Recovery Test ISO Class 5 recovery Test report
IQ-02 Air Change Rate (ACH) Test Minimum 20 ACH Test report
IQ-03 Differential Pressure (DP) Test Maintain DP of ≥ 0.02 in. WC Test report
IQ-04 Temperature and Humidity (RH) Test Temp: 20-24°C; RH: 30-60% Test report
IQ-05 Airflow Visualization Smoke Test Uniform airflow patterns Video documentation
See also  Loss-in-Weight Feeder – IQ Protocol

Detailed Test Cases

Test ID: IQ-01

Procedure: Conduct ISO class recovery tests using viable particle counters.

Acceptance Criteria: ISO Class 5 recovery must be achieved.

Evidence: Test report documenting results.

Test ID: IQ-02

Procedure: Measure air change rates using anemometers.

Acceptance Criteria: Minimum 20 ACH must be recorded.

Evidence: Test report documenting results.

Test ID: IQ-03

Procedure: Measure differential pressure across cleanroom boundaries.

Acceptance Criteria: Maintain DP of ≥ 0.02 in. WC.

Evidence: Test report documenting results.

Test ID: IQ-04

Procedure: Measure temperature and humidity levels using calibrated sensors.

Acceptance Criteria: Temperature: 20-24°C; RH: 30-60%.

Evidence: Test report documenting results.

Test ID: IQ-05

Procedure: Perform airflow visualization using smoke tubes.

Acceptance Criteria: Uniform airflow patterns must be observed.

Evidence: Video documentation of airflow patterns.

Deviations

Any deviations from the acceptance criteria must be documented and assessed for impact on the validation status of the cleanroom. A deviation report must be submitted for review and approval.

Approvals

This protocol requires the following approvals:

  • Validation Manager: ___________________ Date: ___________
  • Quality Assurance: ___________________ Date: ___________
  • Engineering Lead: ___________________ Date: ___________