Nasal/Otic Compounding Vessel (Jacketed SS) – OQ Protocol

Document ID: OQ-001

Version: 1.0

Effective Date: [Insert Date]

Reviewed By: [Insert Name]

Approval Date: [Insert Date]

Operational Qualification Protocol for Nasal/Otic Compounding Vessel

Objective: To validate the operational performance of the Nasal/Otic Compounding Vessel to ensure it meets specified requirements for preparing nasal/otic bulk solutions or suspensions.

Scope: This protocol applies to the Nasal/Otic Compounding Vessel used in the Production area for the preparation of sterile/non-sterile nasal and otic products.

Responsibilities:

  • Validation Team: Responsible for executing and documenting the OQ protocol.
  • Quality Assurance: Responsible for reviewing and approving the OQ protocol and results.
  • Production Personnel: Responsible for operating the equipment as per the established procedures.

Prerequisites:

  • Equipment must be installed and calibrated as per manufacturer’s specifications.
  • Operators must be trained on the use of the Nasal/Otic Compounding Vessel.
  • Relevant SOPs must be reviewed and approved.

Equipment Description:

The Nasal/Otic Compounding Vessel is a jacketed stainless steel vessel designed for the preparation of nasal and otic bulk solutions or suspensions, ensuring optimal agitation and temperature control.

Test ID Procedure Acceptance Criteria Evidence
OQ-01 Verify agitation speed and consistency. Agitation speed within specified range. Calibration records, operator logs.
OQ-02 Measure mixing temperature during operation. Temperature maintained within specified limits. Temperature logs, PLC data.
OQ-03 Document mixing time for batch preparation. Mixing time within defined parameters. Batch records, operator logs.
OQ-04 Audit PLC data for integrity and accuracy. Audit trail complete and accurate. PLC audit report.
See also  Bin/IBC Washer – Deviation Impact Assessment

Detailed Test Cases:

  1. Test ID: OQ-01
    • Procedure: Operate the vessel at the specified agitation speed for a defined duration.
    • Acceptance Criteria: Agitation speed must be within ±5% of the target speed.
    • Evidence: Calibration records and operator logs must be documented.
  2. Test ID: OQ-02
    • Procedure: Measure and record the temperature during mixing.
    • Acceptance Criteria: Temperature must remain within ±2°C of the target temperature.
    • Evidence: Temperature logs and PLC data must be collected.
  3. Test ID: OQ-03
    • Procedure: Document the total mixing time for a defined batch size.
    • Acceptance Criteria: Mixing time must not exceed the established limit.
    • Evidence: Batch records and operator logs must be maintained.
  4. Test ID: OQ-04
    • Procedure: Review the PLC audit trail for completeness and accuracy.
    • Acceptance Criteria: All entries must be timestamped and user-identified.
    • Evidence: PLC audit report must be filed.

Deviations: Any deviations from the acceptance criteria must be documented, and a root cause analysis must be performed.

Approvals:

  • Validation Team Lead: ____________________ Date: __________
  • Quality Assurance Manager: _______________ Date: __________