| URS ID | URS Statement | Risk (H/M/L) | DQ Test Ref | IQ Test Ref | OQ Test Ref | PQ Test Ref | Evidence/Record | Result |
|---|---|---|---|---|---|---|---|---|
| URS-001 | Machine must accurately fill ointment into ophthalmic tubes. | H | DQ-001 | IQ-001 | OQ-001 | PQ-001 | Filling Accuracy Report | Pass/Fail |
| URS-002 | Sealing integrity must ensure no leakage of ointment. | H | DQ-002 | IQ-002 | OQ-002 | PQ-002 | Sealing Integrity Test Report | Pass/Fail |
| URS-003 | Reject audit trail must be maintained for all production runs. | M | DQ-003 | IQ-003 | OQ-003 | PQ-003 | Audit Trail Log | Pass/Fail |
| URS-004 | Fill weight must be within specified limits. | H | DQ-004 | IQ-004 | OQ-004 | PQ-004 | Fill Weight Verification Report | Pass/Fail |