Raw Material Sampling Booth – DQ Protocol

Document Control Number: DQ-001

Version: 1.0

Effective Date: [Insert Date]

Review Date: [Insert Date]

Design Qualification Protocol for Raw Material Sampling Booth

Meta Description: This document outlines the Design Qualification Protocol for the Raw Material Sampling Booth used in API manufacturing, focusing on critical parameters and acceptance criteria.

Tags: Design Qualification, Equipment Validation, API Manufacturing, Sampling Booth

Objective

The objective of this Design Qualification (DQ) protocol is to ensure that the Raw Material Sampling Booth meets the specified requirements for the sampling of API raw materials and intermediates, ensuring product quality and compliance with relevant standards.

Scope

This protocol applies to the Raw Material Sampling Booth located in the Warehouse/Sampling area and covers the validation of its design, installation, and operational performance.

Responsibilities

  • Validation Team: Responsible for executing the DQ protocol and documenting results.
  • Quality Assurance: Responsible for reviewing and approving the DQ protocol and results.
  • Engineering: Responsible for providing technical support and equipment specifications.

Prerequisites

  • Completion of User Requirements Specification (URS) for the Raw Material Sampling Booth.
  • Installation of the Raw Material Sampling Booth in accordance with engineering specifications.
  • Availability of relevant standard operating procedures (SOPs).

Equipment Description

The Raw Material Sampling Booth is designed for the safe and compliant sampling of API raw materials and intermediates. It features HEPA filtration, controlled air velocity, and alarm systems for differential pressure monitoring.

See also  Checkweigher – Validation Summary Report (VSR) Template

Test Plan

Test ID Procedure Acceptance Criteria Evidence
DQ-01 Verify air velocity at sampling points. Air velocity within specified range (e.g., 0.45 – 0.75 m/s). Calibration report and measurement logs.
DQ-02 Conduct HEPA integrity test. HEPA filter integrity confirmed (no leaks detected). Test results and certification of HEPA filters.
DQ-03 Check differential pressure alarms functionality. Alarms trigger at specified DP thresholds. Alarm test logs and response records.

Detailed Test Cases

Test Case DQ-01: Air Velocity Verification

Measure the air velocity at multiple sampling points within the booth using a calibrated anemometer. Document the readings and ensure they fall within the acceptance criteria range.

Test Case DQ-02: HEPA Integrity Testing

Perform a HEPA filter integrity test using a suitable aerosol challenge. Document the pass/fail results and maintain records for future reference.

Test Case DQ-03: Differential Pressure Alarm Testing

Simulate conditions to test the differential pressure alarms. Document the response times and functionality of the alarms in accordance with the specifications.

Deviations

Any deviations from the acceptance criteria must be documented and assessed for impact on product quality. A root cause analysis should be performed, and corrective actions should be implemented as necessary.

Approvals

Prepared By: _______________________ Date: _______________

Reviewed By: _______________________ Date: _______________

Approved By: _______________________ Date: _______________