Sterile Powder Compounding Vessel (Jacketed SS) – IQ Protocol

Document ID: IQ-SPCV-001

Version: 1.0

Effective Date: [Insert Date]

Reviewed By: [Insert Name]

Approval Date: [Insert Date]

Installation Qualification Protocol for Sterile Powder Compounding Vessel

Objective: To verify that the Sterile Powder Compounding Vessel (Jacketed SS) is installed correctly and operates according to the specified requirements for the preparation of sterile bulk solutions before lyophilization.

Scope: This protocol applies to the Installation Qualification of the Sterile Powder Compounding Vessel located in the production area for sterile powders and lyophilized products.

Responsibilities:

  • Validation Manager: Oversee the IQ process and ensure compliance with validation protocols.
  • Quality Assurance: Review and approve the IQ protocol and results.
  • Engineering: Conduct the installation and provide necessary documentation.
  • Production: Operate the equipment and assist in testing.

Prerequisites:

  • Completion of equipment installation as per manufacturer’s specifications.
  • Availability of all necessary documentation (URS, specifications, etc.).
  • Training of personnel on equipment operation and safety procedures.

Equipment Description:

The Sterile Powder Compounding Vessel is a jacketed stainless steel vessel designed for the preparation of sterile bulk solutions. It features controls for agitation speed, temperature, and hold time, with a PLC audit trail for data integrity.

Test ID Procedure Acceptance Criteria Evidence
IQ-001 Verify installation of the Sterile Powder Compounding Vessel. Installation meets all manufacturer specifications. Installation checklist signed off by Engineering.
IQ-002 Check PLC audit trail functionality. Audit trail logs all operations without errors. PLC audit trail report.
IQ-003 Test agitation speed settings. Agitation speed within specified range. Calibration report and test results.
IQ-004 Verify temperature control. Temperature maintained within specified limits. Temperature mapping report.
IQ-005 Check hold time functionality. Hold time accurately recorded and maintained. Hold time log.
See also  Sachets & Stick Packs (Non-Sterile) – IQ Protocol

Detailed Test Cases:

  • Test Case for IQ-001: Inspect the physical installation of the vessel and confirm all connections are secure.
  • Test Case for IQ-002: Simulate operations and verify that the PLC logs all actions accurately without any discrepancies.
  • Test Case for IQ-003: Set the agitation speed to specified levels and measure the actual speed using a calibrated tachometer.
  • Test Case for IQ-004: Use calibrated thermocouples to measure the temperature during operation and compare with set points.
  • Test Case for IQ-005: Record the hold time during a test run and verify against the specified duration.

Deviations: Any deviations from the acceptance criteria must be documented and investigated. A corrective action plan should be developed and approved by Quality Assurance.

Approvals:

  • Validation Manager: ____________________ Date: ____________
  • Quality Assurance: ____________________ Date: ____________
  • Engineering: ____________________ Date: ____________

Data Integrity Checks: Ensure that all data collected during the IQ process is securely stored and that access is controlled. Regular audits should be conducted to verify the integrity of the data.