Document Control
Document Number: OQ-TRD-001
Version: 1.0
Effective Date: [Insert Date]
Review Date: [Insert Date]
Prepared By: [Insert Name]
Approved By: [Insert Name]
Operational Qualification Protocol for Tray Dryer in Solid Dosage Form Production
Objective
The objective of this protocol is to verify that the Tray Dryer operates within specified limits to ensure consistent drying of granules/powder in the production process.
Scope
This protocol applies to the Operational Qualification of the Tray Dryer located in the Production/Drying area, directly impacting the quality of solid dosage forms.
Responsibilities
The Validation Team is responsible for executing this protocol, while the Quality Assurance team will review and approve the results. The Production team will provide necessary support during testing.
Prerequisites
- Installation Qualification (IQ) must be completed and approved.
- All relevant personnel must be trained on the operation of the Tray Dryer.
Equipment Description
The Tray Dryer is designed for drying granules and powders in a controlled environment. It utilizes heated air circulation to ensure uniform temperature distribution and efficient drying times.
Test Plan
| Test ID | Procedure | Acceptance Criteria | Evidence |
|---|---|---|---|
| OQ-01 | Verify temperature uniformity across trays. | Temperature variation ≤ 2°C. | Temperature mapping report. |
| OQ-02 | Measure airflow rates at specified points. | Airflow within specified range as per URS. | Airflow measurement log. |
| OQ-03 | Record drying time for specified batch size. | Drying time within specified range as per URS. | Batch drying report. |
Detailed Test Cases
Test Case OQ-01: Temperature Uniformity
Procedure: Place temperature sensors on each tray and record temperatures at specified intervals during operation.
Acceptance Criteria: All readings must fall within a 2°C range from the set point.
Evidence: Compile a temperature mapping report summarizing findings.
Test Case OQ-02: Airflow Measurement
Procedure: Use an airflow meter to measure airflow at designated points within the dryer.
Acceptance Criteria: Airflow must meet specifications outlined in the URS.
Evidence: Document airflow measurements in a log for review.
Test Case OQ-03: Drying Time Assessment
Procedure: Conduct a drying test with a standard batch size and record the time taken to achieve desired moisture content.
Acceptance Criteria: Drying time must align with URS requirements.
Evidence: Generate a batch drying report detailing the process and outcomes.
Deviations
Any deviations from the acceptance criteria must be documented and investigated. A corrective action plan should be developed and implemented as necessary.
Approvals
Prepared By: ______________________
Date: ______________________
Approved By: ______________________
Date: ______________________