Aseptic Filling Machine (Vials/PFS/Cartridges) – PQ Protocol

Document ID: PQ-001

Version: 1.0

Effective Date: YYYY-MM-DD

Review Date: YYYY-MM-DD

Performance Qualification Protocol for Aseptic Filling Machine in NDDS Production

Objective

To validate the performance of the Aseptic Filling Machine in the aseptic filling of NDDS products, ensuring compliance with regulatory standards and acceptance criteria.

Scope

This protocol applies to the Aseptic Filling Machine used for the aseptic filling of liposomes and lipid nanoparticles in vials, pre-filled syringes (PFS), and cartridges within the production area.

Responsibilities

  • Validation Team: Responsible for executing and documenting the protocol.
  • Quality Assurance: Responsible for reviewing and approving the validation documentation.
  • Production Team: Responsible for providing support during the validation process.

Prerequisites

  • Completion of Installation Qualification (IQ) and Operational Qualification (OQ).
  • Availability of all necessary materials and equipment.
  • Training of personnel involved in the PQ process.

Equipment Description

The Aseptic Filling Machine is designed for the aseptic filling of NDDS products into vials, PFS, and cartridges. It features advanced aseptic controls, fill accuracy mechanisms, and a reject logic audit trail to ensure product integrity.

Test Plan

Test ID Procedure Acceptance Criteria Evidence
PQ-001 Verify fill accuracy Fill accuracy within ±5% Calibration records, fill weight data
PQ-002 Assess aseptic controls No microbial contamination Microbial testing results
PQ-003 Test reject logic 99% rejection of out-of-spec products Audit trail logs

Detailed Test Cases

Test Case 1: Fill Accuracy

Objective: To ensure the fill accuracy of the Aseptic Filling Machine.

See also  Pneumatic Conveying (Dense Phase) – IQ Protocol

Procedure: Conduct fill tests using pre-defined weights and record the results. Compare the results against the acceptance criteria.

Expected Result: All samples should fall within the specified fill accuracy range.

Test Case 2: Aseptic Controls

Objective: To verify the effectiveness of aseptic controls.

Procedure: Conduct microbial testing on filled samples and analyze for contamination.

Expected Result: No microbial growth should be detected in any samples.

Test Case 3: Reject Logic

Objective: To validate the reject logic of the filling machine.

Procedure: Simulate out-of-spec conditions and observe the machine’s response.

Expected Result: The machine should successfully reject all out-of-spec products and log the events.

Deviations

Any deviations from the protocol must be documented and assessed for impact on the validation outcome. A corrective action plan should be established as necessary.

Approvals

Validation Team Lead: ______________________ Date: __________

Quality Assurance: __________________________ Date: __________

Production Manager: ________________________ Date: __________