Design Qualification Protocol for Mixing Tank Equipment in Non-Sterile Liquids
Document Number: DQ-001
Version: 1.0
Effective Date: [Insert Date]
Prepared By: [Insert Name]
Approved By: [Insert Name]
Objective: To establish a Design Qualification (DQ) protocol for the Mixing Tank used in the production of non-sterile liquids, ensuring it meets specified requirements and is suitable for its intended use.
Scope: This protocol applies to the Mixing Tank (Non-Jacketed) utilized in the production/manufacturing area for the mixing of oral liquids, syrups, and suspensions.
Responsibilities:
- Validation Team: Prepare and execute the DQ protocol.
- Quality Assurance: Review and approve the DQ protocol.
- Production Team: Provide input on operational requirements and assist during testing.
Prerequisites:
- Completion of User Requirement Specification (URS).
- Design specifications of the Mixing Tank.
- Training of personnel on the equipment operation.
Equipment Description: The Mixing Tank is a non-jacketed vessel designed for the efficient mixing of non-sterile liquids. It features adjustable agitation speed and is equipped with a control panel for monitoring mixing time.
| Test ID | Procedure | Acceptance Criteria | Evidence |
|---|---|---|---|
| DQ-T01 | Verify agitation speed settings. | Agitation speed must be within the specified range in the URS. | Calibration records and speed test results. |
| DQ-T02 | Measure mixing time during operation. | Mixing time must adhere to the limits defined in the URS. | Time logs and operational records. |
Detailed Test Cases:
- Test Case 1: Validate agitation speed.
- Procedure: Set the agitation speed to the maximum and minimum settings. Measure and document the actual speed.
- Acceptance Criteria: Speed must be within ±10% of the set value.
- Evidence: Calibration log and measurement data.
- Test Case 2: Validate mixing time.
- Procedure: Mix a standard solution and record the time taken to achieve homogeneity.
- Acceptance Criteria: Mixing time must not exceed specified limits in the URS.
- Evidence: Time logs and visual inspection results.
Deviations: Any deviations from the acceptance criteria must be documented, and a root cause analysis must be performed to determine the impact on the equipment’s suitability for its intended use.
Approvals:
- Prepared By: ______________________ Date: ___________
- Reviewed By: ______________________ Date: ___________
- Approved By: ______________________ Date: ___________